3 risks for your home in heavy rain

11.08.2025
Rohrer, Daniel
3 risks for your home in heavy rain

Just imagine: Within a few minutes, masses of water are pelting down from the sky, the sewer system is overloaded - and suddenly the water in your cellar rises.

The 3 risks of heavy rain:
1) Backwater from the sewer system: 42,600 liters
2) Rainwater: 2,250 liters
3) Domestic sewage: 240 liters

Such scenarios are no longer a rarity. Climate change is bringing more extreme weather events, and heavy rain is one of the most dangerous. Many homeowners do not realize that the greatest danger comes from their own home drainage system.



The 3 risks to the average family home are as follows:

Biggest risk - Backflow from the sewer system
Assumption DN 150 pipe is connected to the sewer system


Duration
Backwater height 1m
Backwater height 2m
Backwater height 3m
5 minutes
12'300 liters
17'400 liters
21'300 liters
10 minutes
24'600 liters
34'800 liters
42'600 liters


  • If the water backs up for 5 minutes, 21,300 liters (71 liters/second) of water enter the cellar of a detached house
Check your risk

Medium risk - rainwater during heavy rain


Duration
Heavy rain level 1
Heavy rainfall level 2
Extreme event Level 3
5 minutes
5 l/m²
10 l/m²
15 l/m²
10 minutes
10 l/m²
20 l/m²
25 l/m²


Example: Single-family house heavy rain in 10 minutes
Amount of rain = 20 liters per m²
Roof area = 100 m²
Runoff coefficient = 0.9 (typical tiled roof)


Heavy rainfall level 1
Heavy rainfall level 2
Extreme event level 3
Amount of rain
10 l/m²
20 l/m²
25 l/m²
Amount of water
900 liters
1800 liters
2250 liters


Low risk - domestic wastewater

Minimal as it depends on water consumption (toilet, bath, shower, etc.).

  • Per person per day: approx. 120-130 liters
→ This is approx. 0.1 liters per second or
→ 6 liters in one minute per person

Example: 4 people, 10 minutes
  • 4 people × 6 l/min × 10 min = 240 liters (0.24 m³)


The role of the overflow edge - where the water emerges first

An often underestimated aspect when assessing the risk of backflow is the overflow edge - the point at which the water first emerges in the building.

This depends on the height and is usually graded as follows:

  1. Floor drain or non-bolted manhole cover
  2. Shower tray
  3. WC bowl
  4. Washbasin / washbasin
  5. Condensate connection

Just a few centimetres difference in height can decide whether your cellar stays dry - or floods.

How to proceed - step by step

1. secure the house against backflow from the sewer system.
Installation of a Stop Silent SL13 backflow flap

2. rainwater management
Option A: Allow rainwater to seep away if possible
Option B: Direct rainwater into a retention tank.
This tank releases water into the sewer system with a time delay
and relieves it at peak times.

3. have the domestic wastewater pipe network checked
Check how much water your pipes and manholes can hold in an emergency
Example: Rainwater volume 2250 liters & domestic wastewater 240 liters

4. protection against heavy rain can be planned - act now
A single backwater can cause five-figure damage.


Checklist before installation
https:// www.stopsilent.ch/de/vor-dem-einbau-die-stop-silent-sl13-checkliste

Check your house drainage - now!
Access for Switzerland Stop Silent installation companies
Access for Austria Installation partner Austria
Contact details for the rest of Europe info@stopsilent.eu or by phone 0049 7661 968 9643

Complete concepts from a single source - including installation of the SL 13 backflow flap
Back to the blog
Sitemap
  • Stop Silent® SL13
  • Stop Silent® AS check valves
  • Product overview
  • Contact form
  • General Terms and Conditions
  • Downloads
Lasso Technik AG
Website
Dundi
Website
Contact
Lasso Technik AG
Niklaus von Flüe-Strasse 33
4059 Basel
Switzerland
+41 61 331 40 90
lasso@lasso.ch
Social Media
Copyright © 2024
  • Lasso Technik, AG
  • Data protection
  • Imprint
  • Sitemap
Inquiry
Share
Share this page
Share by email
Share via WhatsApp
FAQ
+41 61 331 40 90